How it works
Room area = length × width (sq ft). Base load = area × 120 BTU per sq ft (Indian rule of thumb). Ceiling above 10 ft: multiply by ceiling ÷ 10 — a taller room holds more air to cool. Sun exposure: shaded × 0.9, some sun × 1.0, full sun × 1.1. Occupants: add 600 BTU per hour for each person above the first two. Tonnage = total BTU ÷ 12,000. Round up to the nearest standard size (0.8, 1, 1.5, 2, 2.5, 3, 4, 5 tons).
How to read the formula: room area is length times width in square feet, and the base cooling load is area multiplied by 120 BTU per square foot — the Indian rule of thumb for a typical room, higher than the 20 BTU per square foot used in the US guide because Indian summers, construction and window sizes differ. A ceiling above 10 ft multiplies the load by ceiling height divided by 10, since a taller room holds more air to cool. Sun exposure adjusts it by 0.9 for shade, 1.0 for some sun and 1.1 for full sun, and each person above the first two adds 600 BTU per hour of body heat. Total BTU divided by 12,000 gives tonnage, because one ton of cooling removes 12,000 BTU of heat per hour, and the answer is rounded up to the nearest standard size — 0.8, 1, 1.5, 2, 2.5, 3, 4 or 5 tons. The rule covers one room; a whole home needs a proper Manual J calculation.
Worked example: a 12 × 15 ft room is 180 sq ft, so the base load is 180 × 120 = 21,600 BTU per hour. With a 10 ft ceiling, some sun and 2 occupants there is no adjustment, so 21,600 ÷ 12,000 = 1.80 tons — round up to a 2-ton AC. A 10 × 12 ft room with a 12 ft ceiling, full sun and 4 occupants needs 120 × 120 × 1.2 × 1.1 + 1,200 = 20,208 BTU, or 1.68 tons — again a 2-ton AC.
Second worked example: a 12 × 10 ft bedroom in a Pune flat — 120 sq ft, a 10 ft ceiling, shaded windows and two occupants. Base load = 120 × 120 = 14,400 BTU/hr. No ceiling adjustment at 10 ft, shaded means × 0.9, and two occupants add nothing: 14,400 × 0.9 = 12,960 BTU/hr, or 1.08 tons — so a 1.5-ton AC is the right standard size, with about 0.42 tons of headroom.
How to choose
Between two standard sizes, the choice is rarely just the number. A 1.5-ton inverter AC suits the Pune bedroom above because an inverter slows its compressor once the room is cool, so the extra 0.42 tons of headroom costs little in electricity and keeps humidity down. A fixed-speed AC is less forgiving: oversized, it cools the room in minutes, switches off, and never runs long enough to pull moisture from the air, leaving the room cold and clammy — which is why the calculator rounds up only to the next size, never two. Step up a size when the room breaks the rule’s assumptions: a top-floor bedroom in Nagpur with a west-facing window can need 20–30% more cooling than the base rule, well above the 10% the full-sun factor adds, and a kitchen or a room with a large glass wall is the same story. Step down, or accept the smaller size, for a shaded ground-floor room that is used only at night. And buy for the hottest month, not the average one — an AC that is right in March and wrong in May is the wrong AC.
Baseline: 120 BTU per sq ft (the Indian rule of thumb; the US ENERGY STAR guide uses 20 BTU per sq ft). One ton of cooling = 12,000 BTU per hour. Standard AC sizes: 0.8, 1, 1.5, 2, 2.5, 3, 4 and 5 tons.
Frequently asked questions
What does 1 ton of AC mean?
One ton of cooling removes 12,000 BTU of heat per hour. It has nothing to do with the weight of the machine — it comes from the cooling power of a ton of ice melting over a day.
Should I buy a bigger AC than the calculator says?
No — an oversized AC cools the room fast and switches off before it has dehumidified the air, leaving the room cold and clammy. A slightly undersized AC runs longer and dehumidifies better. Round up only to the next standard size.
Why does sun exposure change the answer?
A room with large west-facing windows gains a lot of solar heat in the afternoon. Full sun adds about 10% to the load; a shaded room needs about 10% less.
Does ceiling height really matter?
Yes for tall ceilings: a 12 ft ceiling holds 20% more air than a 10 ft one, so the load rises by the same proportion. Below 10 ft the effect is small, so this calculator only adjusts above 10 ft.
Is this the same as a Manual J calculation?
No. Manual J is the proper engineering method — it measures windows, insulation, walls, orientation and local climate. This calculator is a rule-of-thumb guide for a single room; for a whole home, get a Manual J done.