← All tools/Calculators/Everyday/Inverter Battery Calculator

Inverter Battery Calculator

How long will your inverter battery last on a power cut — and what size battery do you need for the backup you want?

Add up the watts of everything the inverter will run — fans, lights, TV, Wi-Fi router and chargers. A ceiling fan is about 75 W, an LED bulb about 10 W, a TV about 100 W.

Backup time

4.08 h

4 h 5 min of backup at 300 W

Backup
4.08 h
Wanted
4 h

Backup 4.08 h · wanted 4 h — covers the target

Usable energy1,224 Wh
Battery size needed for 4 h147 Ah
Suggested inverter rating400 VA

Estimate only — actual backup varies with battery age, temperature and load.

How it works

Backup hours = Ah × volts × depth of discharge × efficiency ÷ load (W)
Usable energy (Wh) = Ah × volts × depth of discharge × efficiency
Battery Ah needed = hours wanted × load ÷ (volts × depth of discharge × efficiency)
Suggested inverter VA = load ÷ 0.8, rounded up to the nearest 50 VA
Depth of discharge: tubular 80% · flat-plate 50% · lithium 90%

Worked example — a 150 Ah, 12 V tubular battery (80% DoD) on an 85% efficient inverter, running a 300 W load: 150 × 12 × 0.8 × 0.85 ÷ 300 = 4.08 hours, about 4.1 hours (4 h 5 min). Usable energy is 150 × 12 × 0.8 × 0.85 = 1,224 Wh. For a 4-hour backup at 300 W you need 147 Ah, and the inverter should be rated at least 400 VA.

A simpler sum that skips efficiency (150 × 12 × 0.8 ÷ 300) gives 4.8 hours — too optimistic, because the inverter itself uses power. Battery age, temperature and load all change the real figure, so treat the answer as an estimate.

Frequently asked questions

What is depth of discharge (DoD)?

The share of a battery’s capacity you can safely use. A tubular battery can be discharged to about 80%, a flat-plate battery to about 50% and a lithium battery to about 90%. Draining a lead-acid battery deeper than its DoD shortens its life sharply.

Why does my battery last less than the calculator says?

Age is the usual reason — a two-year-old battery may hold only 70–80% of its rated capacity. Heat, a load higher than the rated watts, and the inverter’s own losses all cut backup time too. Treat the answer as an estimate for a healthy battery.

How do I add up my load in watts?

Add the wattage of everything the inverter will run at once: a ceiling fan is about 75 W, an LED bulb about 10 W, a TV about 100 W and a Wi-Fi router about 10 W. Four fans, four bulbs, a TV and a router come to roughly 450 W.

What size inverter do I need?

Divide the load in watts by 0.8 and round up to the nearest 50 VA — a 300 W load needs about 400 VA, and a 500 W load needs about 650 VA. Buying a little headroom also covers the brief surge when a fan or fridge motor starts.

Can I add a second battery later?

Yes, in parallel — two 150 Ah batteries give 300 Ah at the same voltage. For the longest life, add a battery of the same type, voltage and age as the one already fitted; mixing an old battery with a new one drags the new one down.

More tools

Tell us what you think

Loving this tool, or stuck on something? Tell us — it takes a minute.

We’ll only use your name and email to reply if needed. The tool and page are filled in for you.